- Small microfuge for research, biotechnology and medical laboratory.
- Bright LCD – Display
- Large capacity 24 x 1,5 – 2,2 ml
- Topspeed 14.800 rpm (16.163 x g)
- Rapid acceleration and deceleration
- Low temperature increase during run
- Easy handling, big buttons
- Short and continuous run, 99 min. timer
- Two acceleration and deceleration curves
- Motorized lid lock
- Maintenance-free induction drive motor
Sigma 1-14 Part. no. 90616 (230V, 50/60 Hz)
Sigma 1-14 1-14K brochure 2018
For the refrigerated version of the 1-14, click here.
Rotors, accessories & tubes for the SIGMA 1-14 centrifuge
Order No. | Description | Max. rpm | Max. rcf |
---|---|---|---|
12082 | Angle rotor made of aluminium, 12 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882 | 14.800 | 15.183 |
12083 | Angle rotor made of alumnium, 18 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, or 18 x 0,24/0,4 ml e.g. no.15014, (2 lines) incl. polysulfone lid no.17882 | 14.800 | 14.448 /15.673 |
12084 | Angle rotor made of Aluminium, 24 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882 | 14.800 | 16.163 |
12092 | Angle rotor made of polypropylene, 12 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882 | 14.800 | 15.183 |
12093 | Angle rotor made of polypropylene, 18 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, oder 18 x 0,24/0,4 ml e.g. no.15014, (2 lines) incl. Polysulfone no.17882 | 14.800 | 14.448 /15.673 |
12094 | Angle rotor made of polypropylene, 24 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882 | 14.800 | 16.163 |
11026 | Microhematocritrotor, suitable for 24 capillary tubes Ø 1,4 x 50 mm, 35 µl no.15028, incl. reader no. 17028, usable with reader no.17026 | 13.000 | 11.903 |
12085 | Angle rotor aluminium 16 x 1.5/2.2 ml or 16 x 0.5/0.7 ml | 14.800 | 15.672 |
Order No. | Description | Suitable For: |
---|---|---|
13000 | Adapter for reaction vials 0,25/0,4 ml no.15014 | 12082/12083/12084 /12092/12093/12094 |
13002 | Adapter for reaction vials 0,5/0,7 ml, Ø 7,9/10 x 28/31 mm no.15005 | 12082/12083/12084 /12092/12093/12094 |
13021 | Adapter for PCR-tube 0,2 ml | 12082/12083/12084 /12092/12093/12094 |
17882 | Spare polysulfone lid for Angle rotors of Sigma 1-14 | 12082/12083/12084 /12092/12093/12094 |
17026 | Reader for use with microhematocritrotor | 11026 |
17005 | Capillary tube sealing putty (6 plates) | 11026 |
Order No. | Description | Suitable For: |
---|---|---|
15028 | Microhematocrit capillary tubes, heparinized, 35 µl, Ø 1,4 x 50 mm, 200 pcs. per pack | 11026 |
15014 | Reaction-vials made of polypropylene 0,4 ml, 100 pcs. per pack | 13000/12083/12093 |
15005 | Reaction-vials 0,5 ml, 100 pcs. per pack | 13002 |
15008 | Reaction-vials 1,5 ml, 100 pcs. per pack | 12082/12083/12084 /12092/12093/12094 |
15040 | Reaction-vials 2,2 ml, 100 pcs. per pack | 12082/12083/12084 /12092/12093/12094 |
Electric Supply | 230 V, 50/60 Hz; 100-120 V, 50/60 Hz |
---|---|
Power consumption, induction drive motor | 95 W |
Acceleration and deceleration curves | 2 |
Max. rotational (1/min) | 14.800 |
Min. rotational (1/min) | 200 |
Max. capacity (ml) | 24 x 2.2 |
Max. gravitational | 16.163 x g |
Min. gravitational | 2 x g |
Max. temp. increase rotor 12092 20 min / continuous run | 9°C / 13°C |
Max tem. increase rotor 12092 20 min / continuous run | 10°C / 11,1°C |
Max. acceleration rotor 12092 | 13 sec. |
Max acceleration rotor 12094 | 14 sec. |
Max. deceleration rotor 12092 | 11 sec. |
Max deceleration rotor 12094 | 12 sec. |
Interference suppression | EN 61326 |
Dimensions: height x width x depth (mm) | 176 x 226 x 212 |
Weight without rotor (kg) | 5,4 |
Noise level at max. speed | < 60 dB |
Max. kinetic ernegie (Nm) | 1721 |
Categorised in SIGMA Microfuges